Sunday, March 27, 2011

Lorna Morgan Blue Bath

QUILMES, 2 OUT OF 3 building would BALCONIES IN BAD CONDITION ITS MASS



FALLS FROM BALCONY TO BE GENERATED AND GENERATE terrible misfortune, MANY OF WHICH WILL HIDE NO ACTS OF GOD.

cocktail here in Quilmes alarming lack of scruples OF THOSE RESPONSIBLE FOR YOUR WALLET WORKS PRIORITY ON THE SAFETY OF SEIZED BUYERS LACK OF FITNESS PROFESSIONAL AND DISABILITY IRRESPONSIBILITY PUBLIC BY THE CITY IN ITS ROLE OF COMPTROLLER , They increase the likelihood of occurrence of these tragedies every day.


There are at least 22 reasons that can be completed in the fall of a balcony, then the cite
:

1. At the time of casting, when the concrete is fresh, it can be washed by rain water.

2. Fresh concrete can become dehydrated violent excess heat or wind.

3. Excess overload: load much higher than anticipated in the calculation.

4. Aesthetic modification was performed on the balcony without making a

5. During holidays or meetings, 20 minutes enough for the whole family moves to the balcony. "builders have told us what will be the minimum loads to be calculated for a balcony?

6. Errors in the calculation of the structure.

7. Insufficient iron section

8. Insufficient concrete section

9. Poor execution of work, unskilled personnel.

10. Excess water-cement ratio

11. Poor concrete compaction

12. Concrete applied: No specific resistance required, there were no enzayos to compression, the authority not required at the time of the habilitaciòn.Las empresas constructoras no o realizan.

13. Falta de curado

14. Cantidad de hierros menor a la especificada en el cálculo, inadecuada ejecución por parte de los rofesionales de la obra.

15. Equivocada disposición de los hierros, Inadecuada ejecuciòn

16. Falta de adherencia entre el hormigón y el hierro por estar este último sucio.

17. Defecto de los materiales.

18. El acero no responde a las exigencias de las normas IRAM que regulan su calidad.

19. Las barras no tienen el diámetro especificado.Falta de supervisiòn.

20. El cemento no responde a las exigencias de las normas IRAM que regulan su calidad. Error y falta quality controls.

21. Excessive storage time storage conditions
cemento.Malas
22. Aggregates present in concrete, will they have a lot of organics and / or land? Will there be various quality control work on the type of sand, the type of stone and boulders used? Will there be any legislation that guides the staff performing the work?

0 comments:

Post a Comment